Reheat Condensing Turbine

Line Up

Automatic-double-extraction Reheat Turbine
2-casing single exhaust flow type

Rated output 149,000kW
Main steam pressure 16.6MPag
Main steam temperature 566°C
Reheat steam temperature 538°C
Extraction pressure 3.5/0.69MPag
Exhaust pressure 5.07kPa abs.
Automatic-double-extraction Reheat Turbine Section D

Reheat Turbine - Axial flow

Suitable for combined cycle and low-floor installation plants
For HP-EHC application

Rated output 200,000kW
Main steam pressure 12.7MPag
Main steam temperature 538°C
Reheat steam temperature 538°C
Exhaust pressure 8.63kPa abs.
Reheat Turbine Section D

Automatic-extraction Reheat Turbine
2-casing double exhaust flow type

Rated output 300,000kW
Main steam pressure 13.9MPag
Main steam temperature 535°C
Reheat steam temperature 535°C
Extraction pressure 0.25MPag
Exhaust pressure 6.27kPa abs.
Automatic-extraction Reheat Turbine Section D

Reheat Turbine - 2-casing type

For large-capacity reheat turbine

Rated output 500,000kW
Main steam pressure 16.6MPag
Main steam temperature 538°C
Reheat steam temperature 538°C
Exhaust pressure 10.2kPa abs.
Reheat Turbine - 2-casing type Section D

Figures above are typical data, subject to the design and optimization.